The HI5221 is an advanced research grade benchtop pH/mV meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity.
The HI5221 features a universal BNC connection for use with the expansive line of pH and ORP electrodes that Hanna Instruments offers. The meter is supplied with the HI1131B glass body, double junction, combination pH electrode that operates over a wide temperature range from 0 to 100 °C. All readings are automatically compensated for temperature variations with the separate HI7662-T temperature probe that is included.
The HI5221 can be calibrated up to five points with a choice of eight pre-programmed buffers or five custom buffers. The HI5221 features Hanna’s exclusive CAL Check™ to alert the user of potential problems during the pH calibration process. Indicators displayed during calibration include “Electrode Dirty/Broken” and “Buffer Contaminated.” The overall probe condition based on the offset and slope characteristic of the electrode is displayed as a percentage after calibration is complete. The calibration data including date, time, buffers used, offset and slope can be accessed at any time along with the current measurement by selecting the Good Laboratory Practice (GLP) display option.
Three selectable logging modes are available: automatic, manual and AutoHold logging. Up to 100,000 data points can be recorded in 100 lots with 50,000 records max/lot and exported to a computer for data review and storage.
pH Range | -2.000 to 20.000 pH |
---|---|
pH Resolution | 0.1, 0.01, 0.001 pH |
pH Accuracy (@25ºC/77ºF) | ±0.1 pH, ±0.01 pH, ±0.002 pH ±1 LSD |
pH Calibration | automatic, up to five point calibration, eight standard buffers available (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01,12.45) and five custom buffers |
pH Temperature Compensation | automatic or manual from -20.0 to 120.0 °C |
mV Range | ±2000 mV |
mV Resolution | 0.1 mV |
mV Accuracy | ±0.2 mV ±1 LSD |
Relative mV Offset Range | ±2000 mV |
Temperature Range | -20.0 to 120.0 ºC, -4.0 to 248.0 °F, 253.15 to 393.15 K |
---|---|
Temperature Resolution | 0.1 °C, 0.1 °F, 0.1 K |
Temperature Accuracy | ±0.2 °C, ±0.4 °F, ±0.2 K |
Electrode/Probe | HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included) |
---|---|
Temperature Probe | HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included) |
GLP | calibration data including date, time, buffers used, offset and slope |
Logging | record: 100,000 data point storage, 100 lots with 50,000 records/lot; interval: settable between 1 second and 180 minutes max log time; type: automatic, manual, AutoHold |
Input Channels | 1 - pH/ORP |
Display | color graphic LCD with on-screen help, graphing, and custom color configuration |
Connectivity | USB |
Environment | 0 to 50°C (32 to 122°F; 273 to 323 K), RH max 95% non-condensing |
Power Supply | 12 VDC adapter (included) |
Dimensions | 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”) |
Weight | 1.2 kg (2.64 lbs.) |